After a unit of whole blood is spun in a centrifuge, it settles into layers: red cells at the bottom and plasma on top. A plasma expressor presses the bag so that the plasma flows into a satellite bag while the red cells stay behind. It is one of the simplest pieces of equipment in component separation, but the choice between a manual and an automatic model changes how much attention each bag needs.
Bioline India makes both types in Indore. This guide uses our BPE 2008 manual and BEPE 2008E automatic expressors as examples.
How a manual expressor works
The bag hangs between a back plate and a spring loaded pressure plate. The operator releases the plate, it presses the bag evenly, and plasma flows out through the tube. The operator watches the tube and closes it by hand as soon as red cells start to appear.
Manual expressors are simple, light and need no power. Our BPE 2008 has an acrylic pressure plate, a stainless steel 304 hinge that does not corrode, and a powder coated cabinet built for continuous use.
The limit is attention. The operator has to watch every bag, and stopping a little late lets red cells into the plasma.
How an automatic expressor works
An automatic expressor adds a sensor and a clamp. Our BEPE 2008E watches the tube with an infrared sensor. When red cells reach the sensor, a clamp driven by a geared motor closes the tube at once. The operator can load the next bag instead of watching the first one.
The BEPE 2008E can also connect to a compo scale (optional), so the weight of each component can be checked as it is separated.
Which one suits you?
- A small blood bank or a lab that separates a few units a day can work well with manual expressors.
- A blood bank that separates many units, or wants each separation to stop at the same point every time, gains from automatic expressors.
- Many blood banks keep both: automatic units for routine work, and a manual unit as a backup that needs no power.
What to check before you buy
- Even pressure: the pressure plate should press the whole bag evenly.
- Sensor and clamp: on automatic models, ask what the sensor detects and how fast the clamp closes.
- Build: corrosion resistant hinges and a cabinet finish that stands daily cleaning.
- Fit with your bags: check that your bag sizes hang and press correctly.
- Connection to a compo scale, if you weigh components.
- Service: who maintains the sensor and clamp, and how fast spares arrive.
Bioline India plasma expressors
- BEPE 2008E Automatic Plasma Expressor: infrared sensor, motorised tube clamp, optional compo scale interface
- BPE 2008 Manual Plasma Expressor: acrylic pressure plate, stainless steel 304 hinge, no power needed
We also make refrigerated centrifuges, compo scales and sterile connecting devices for component separation. Ask us for a quote.